User’s Manual of ICS-10x
-45-
1. Connect the converter with the IP camera for RS-485 interface like PLANET product: “ICA-651”.
2. Connect the converter with the control keyboard for RS-485 interface like PLANET product: “CAM-KB300”.
ICS-10x – Master: be configured as Pair-Connection-Local
3. From Web interface, login the ICS-10x with IP address = 192.168.0.100, set up the operation mode of this unit to be
Pair Connection-Local (master)
Figure 4-50 Pair Connection – Local, operation mode configuration
4. Set the Serial Port mode of ICS-10x-Master to RS-485.
Figure 4-51 Pair Connection – Local, serial port configuration
ICS-10x – Slave: be configured to Pair-Connection-Remote
5. From Web interface, login the ICS-10x with IP address = 192.168.0.101, set up the operation mode of this unit to be
Pair Connection-Local (master)