Planet Technology GT-902 Manuel d'utilisateur

Naviguer en ligne ou télécharger Manuel d'utilisateur pour Mise en réseau Planet Technology GT-902. Planet Technology GT-902 User's Manual Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer

Résumé du contenu

Page 1 - User's Manual

User's Manual GT-902 GT-902S GT-905A GT-906A15 / GT-906B15 GT-906A60 / GT-906B60 10/100/1000Base-T to 1

Page 2

2. HARDWARE DESCRIPTION This product provides three different running speeds – 10Mbps, 100Mbps and 1000Mbps in the same Managed Media Converter and a

Page 3 - TABLE OF CONTENTS

2.1.1 LED Indicators LED Color Description PWR Green Lit: When +5VDC power detected. Lit: To indicate the link through that fiber port is succes

Page 4

2.2 Install the Converter This section describes how to install your Managed Media Converter and make connections to the Managed Media Converter. Ple

Page 5

#Notice: Please refers to APPENDIX-A for detailed wiring information of the Managed Media Converter. To prevent from optic acceptor malfunction, chec

Page 6 - Application

2.2.2 Chassis Installation and Rack Mounting To install the Managed Media Converter in a 10-inch or 19-inch with standard rack, follow the instructio

Page 7 - 1.4 Product Features

Figure 2-6 Mounting the Chassis in a Rack -11-

Page 8 - 1.5 PRODUCT SPECIFICATION

3. MEDIA CONVERTER MANAGEMENT This chapter describes how to manage the Managed Media Converter. Topics include: - Overview - Management methods -

Page 9

3.2.1 Web Management The PLANET Managed Media Converter provides a built-in browser interface. You can manage the Managed Media Converter remotely by

Page 10 - 2. HARDWARE DESCRIPTION

3.2.3 PLANET Smart Discovery Utility For easily list the Managed Media Converter in your Ethernet environment, the Planet Smart Discovery Utility fro

Page 11 - #Notice:

3. This utility show all necessary information from the devices, such as MAC Address, Device Name, firmware version, Device IP Subnet address, also c

Page 12 - 2.2 Install the Converter

-2- Trademarks Copyright © PLANET Technology Corp. 2008. Contents subject to which revision without prior notice. PLANET is a registered trademark of

Page 13

4. WEB MANAGEMENT The GT-90X Managed Media Converter provide Web interface for management function configuration and make the Managed Media Converte

Page 14

4.2 System 4.2.1 System Information The System Information Web page provides information for the current device. System Information Web page helps ne

Page 15

4.2.2 IP Configuration The IP Configuration includes the DHCP Client, IP Address, Subnet Mask, Gateway and Description. The screen in Figure 4-3 appe

Page 16 - 3.2 Management Methods

4.2.3 Password Setting This function provides administrator to secure Web login. The screen in Figure 4-4 & 4-5 appears and Table 4-3 describes t

Page 17 - 3.2.2 SNMP Management

The Password Setting Web page includes the following configurable data: Login Name Displays the user name (admin). Old Password Enter the old passwor

Page 18

Press “Browser” button to find the firmware location administrator PC, The screen in Figure 4-7 appears Figure 4-7 Firmware Upgrade Web page screen

Page 19

Figure 4-9 Firmware Upgrade Web page screen When firmware upgrade process is completed then the following screen appears, please click “here” to re

Page 20 - 4. WEB MANAGEMENT

Figure 4-11 Login Web page screen -23-

Page 21 - 4.2 System

4.2.5 SNMP Management This function provides SNMP Management and SNMP Trap Receiver Configuration function of the Managed Media Converter and the scr

Page 22

Figure 4-13 SNMP Trap Receiver Configuration Web page screen The SNMP Trap Receiver Configuration Web page includes the following configurable data

Page 23 - 4.2.3 Password Setting

-3- TABLE OF CONTENTS 1. INTRODUCTION ...

Page 24 - 4.2.4 Firmware Upgrade

4.2.6 Factory Default This function provides Factory Default function of the Managed Media Converter and the screen in Figure 4-14 & 4-15 & 4

Page 25

Figure 4-16 Login Web page screen 4.2.7 System Reboot This function provides System Reboot function of the Managed Media Converter and the screen in

Page 26

Figure 4-18 System Reboot Web page screen Figure 4-19 Login Web page screen -28-

Page 27

4.3 Port Management 4.3.1 Port Configuration This function allows displaying TP / Fiber port status. The Link Status in the screen displays the curre

Page 28

Flow Control Allow Disable or Enable Flow Control of TP or Fiber port. • Enable – IEEE 802.3x Flow Control is enabled on Full-Duplex mode or Backpres

Page 29

Figure 4-21 Port Configuration-Ingress Rate Limit Web Page screen Figure 4-22 Port Configuration-Egress Shaping Web Page screen -31-

Page 30 - 4.2.6 Factory Default

4.3.2 Port Status This function allows displaying TP / Fiber port detail status, such as Link Status, Duplex Mode, Flow control, Speed and Auto negot

Page 31 - 4.2.7 System Reboot

4.3.3 Port Statistics This function allows displaying TP / Fiber port detail Statistics, press the “Clear” button to clear current counter informatio

Page 32

4.4 Converter Configuration This function provides useful setting for the Managed Media Converter, such as Maximum Packet length, Loop detection, sto

Page 33 - 4.3 Port Management

Storm Filter Timer Provide storm Filter Timer setting and the available options are: 800ms 400ms 200ms 100ms Default mode is 800ms. Apply button Pr

Page 34

-4- 4.5.3 Q-in-Q VLAN Setting...

Page 35

802.1Q Tag User Priority CFI VLAN ID (VID) 3 bits 1 bits 12 bits TPID (Tag Protocol Identifier) TCI (Tag Control Information) 2 bytes 2 by

Page 36 - 4.3.2 Port Status

Default VLANs The Managed Media Converter initially configures one VLAN, VID = 1, called "default." The factory default setting assigns all

Page 37 - 4.3.3 Port Statistics

Figure 4-28 VLAN Group Web Page screen The VLAN Group Web page includes the following configurable data: VLAN Mode Provide Disable or enable the IEE

Page 38 - 4.4 Converter Configuration

4.5.2 VLAN Per Port Setting This function provides IEEE 802.1Q VLAN per port setting for TP and Fiber port of Managed Media Converter. Press the “App

Page 39 - 4.5 VLAN

4.5.3 Q-in-Q VLAN Setting When enable Q-in-Q function, Managed Media Converter can insert or remove 4-bytes Q-in-Q tag in the received 802.3 frames

Page 40

4.6 Quality of Service Quality of Service (QoS) is an advanced traffic prioritization feature that allows you to establish control over network traff

Page 41 - 4.5.1 VLAN Group

The Quality of Service Web page includes the following configurable data: Qos Mode Provide 4 different QoS mode for operation, the available options

Page 42

Figure 4-33 IP Address Priority Web Page screen Figure 4-34 IP DSCP Priority Web Page screen -43-

Page 43 - 4.5.2 VLAN Per Port Setting

4.7 OAM Setup 4.7.1 Local TS-1000 OAM Setup This function provides Local TS-1000 OAM Setup of Managed Media Converter. Press the “Apply” button to sa

Page 44 - 4.5.3 Q-in-Q VLAN Setting

4.7.2 Remote TS-1000 OAM Setup The Remote TS-1000 OAM Setup is an advanced remote device monitor feature that allows you to Remote monitor and automa

Page 45 - 4.6 Quality of Service

1. INTRODUCTION 1.1 Package Contents Check the contents of your package for following parts: ● Managed Gigabit Ethernet Media Converter x1 ● CD-ROM

Page 46

Figure 4-37 GT-90x Remote TS-1000 OAM Setup Web Page screen #Notice: Please use the PLANET GT-80x and GT-90x as the Remote device.

Page 47

4.7.3 TS-1000 Loop Back Test The TS-1000 Loop Back Test allows manual run this loop back test to check the interconnection between two Media Converte

Page 48 - 4.7 OAM Setup

Figure 4-38 Remote TS-1000 Loop Back Test Web Page screen The TS-1000 Loop Back Test Web page includes the following configurable data: TS-1000 Loop

Page 49

4.7.4 802.3ah Setup When enable 802.3ah OAM function, all 802.3ah OAMPDU packets will trap to embedded CPU. Software will implement auto discovery pr

Page 50

#Notice: 1. The 802.3ah function must work with manageable device that supports 802.3ah function. 2. Please use the PLANET GT-90x as the Remote devi

Page 51 - 4.7.3 TS-1000 Loop Back Test

Figure 4-40 802.3ah Loop Back Test Web Page screen The 802.3ah Loop Back Test Web page includes the following configurable data: 802.3ah Loop Back T

Page 52

4.8 Security This function provides TCP / UDP Filter setting of Managed Media Converter. Press the “Apply” button to save the current configuration o

Page 53 - 4.7.4 802.3ah Setup

4.9 Logout This function provides Logout function of Managed Media Converter, when the “Are you sure to logout” pop window appears; press the “OK” bu

Page 54

5. TROUBLESHOOTING This chapter contains information to help you solve problems. If the media converter is not functioning properly, make sure the me

Page 55

APPENDIX A NETWORKING CONNECTION A.1 Device‘s RJ-45 Pin Assignments 1000Mbps, 1000Base T RJ-45 Connector pin assignment Contact MDI MDI-X

Page 56 - 4.8 Security

-2- 1.3 About the Managed Media Converter The Managed Media Converter GT-90x provide conversion between 10/100/1000Base-T and 1000Base-SX /LX networ

Page 57 - 4.9 Logout

There are 8 wires on a standard UTP/STP cable and each wire is color-coded. The following shows the pin allocation and color of straight cable and cr

Page 58 - 5. TROUBLESHOOTING

-57- A.4 Power Information The power jack of Managed Media Converter is with 2.5mm in the central post and required +5VDC power input. It will confor

Page 59 - 2 1 3 6

PLANET TECHNOLOGY CORPORATION e-mail: [email protected] http://www.planet.com.tw 11F, No. 96, Min Chuan Road, Hsin Tien, Taipei, Taiwan, R.O.C. T

Page 60

1.4 Product Features  Complies with IEEE 802.3 10Base-T, IEEE 802.3u 100Base-TX, IEEE 802.3ab 1000Base-T, IEEE 802.3z 1000Base-SX/LX  O

Page 61 - A.5 Available Modules

; TS-1000 OAM / IEEE 802.3ah OAM / Loop Back Test ; 16 TCP / UDP Filter groups ; Password setting, IP setting and devices description setting thro

Page 62 - 27, Oct., 2008

Power Consumption 3.8 Watts/ 13 BTU (maximum) Power Input DC 5V / 2A Dimensions 94 x 70 x 26mm (W x D x H) Operator Environment Operating temper